Overview
CerAnode™ Halar® Cable is engineered for impressed current cathodic protection (ICCP) systems requiring exceptional chemical resistance and long-term durability in aggressive operating environments. Insulated with ethylene chlorotrifluoroethylene (ECTFE), Halar® provides outstanding protection against acids, alkalis, hydrocarbons, moisture, and other corrosive chemicals commonly encountered in industrial and marine applications.
Designed for dependable electrical performance, CerAnode™ Halar® Cable delivers reliable current transfer between rectifiers, anodes, junction boxes, and protected structures while maintaining insulation integrity under demanding service conditions. Available in a variety of conductor sizes, insulation thicknesses, and custom lengths, the cable can be configured to meet a wide range of cathodic protection requirements.
Key Features & Benefits
ECTFE (Halar®) Insulation
High-performance ECTFE insulation provides exceptional resistance to chemicals, abrasion, moisture, and environmental degradation in harsh industrial applications.
Reliable Electrical Performance
High-quality copper conductors ensure efficient current transfer throughout impressed current cathodic protection systems.
Designed for Aggressive Environments
Engineered for long-term performance in refineries, chemical processing facilities, marine environments, and other applications where conventional cable insulation may deteriorate.
Flexible System Integration
Compatible with rectifiers, MMO anodes, junction boxes, test stations, and other cathodic protection system components.
Multiple Configuration Options
Available in various conductor sizes, insulation thicknesses, colors, and custom lengths to meet project-specific requirements.
Typical Applications
- Impressed current cathodic protection (ICCP) systems
- Chemical processing and petrochemical facilities
- Refineries and industrial plants
- Marine and offshore corrosion protection systems
- Aboveground and underground storage tanks
- Pipelines and other critical infrastructure
Installation & Accessories
Flexible Installation Methods
Suitable for direct burial, conduit, cable tray, and industrial routing applications depending on project requirements.
Reliable Electrical Connections
Compatible with compression connectors, cable splice kits, underwater connectors, and junction boxes for secure field terminations.
System Integration
Designed for seamless integration with CerAnode™ rectifiers, anodes, reference electrodes, test stations, and monitoring equipment.
Custom Configuration Options
Available with factory-installed terminations, custom cable lengths, conductor sizes, and project-specific configurations.
Long-Term Field Performance
Engineered to maintain electrical performance and insulation integrity while minimizing maintenance throughout the service life of the cathodic protection system.
Documentation
- Technical Data SheetDownload 126 KB
Engineered for your application
No two cathodic protection systems are identical. Tell us the current requirement, electrolyte and installation constraints and we will configure the anode around them.
HMWPE Cable
CerAnode™ HMWPE Cable is engineered for long-term performance in impressed current cathodic protection (ICCP) and galvanic cathodic protection systems. Manufactured with a high molecular weight polyethylene (HMWPE) jacket, this cable provides exceptional resistance to abrasion, moisture, chemicals, and mechanical damage, making it ideal for demanding underground, marine, and industrial installations.
Kynar® Cable
CerAnode™ Kynar® Cable is engineered for impressed current cathodic protection (ICCP) systems operating in the most demanding industrial and corrosive environments. Insulated with polyvinylidene fluoride (PVDF), Kynar® provides exceptional resistance to chemicals, abrasion, ultraviolet (UV) exposure, and elevated temperatures, making it an ideal choice for critical corrosion protection applications where long-term reliability is essential.
Loresco® Coke
CerAnode™ Loresco® Coke Breeze is a high-purity carbon backfill designed to enhance the performance and service life of impressed current cathodic protection (ICCP) groundbeds. Surrounding the anode with a conductive carbon medium reduces groundbed resistance, improves current distribution, and promotes efficient current discharge into the surrounding electrolyte.
Ventrolizer™ (VENT)
CerAnode™ Ventrolizer™ Vent Pipe Assemblies are engineered to safely vent gases generated within cathodic protection systems while preventing moisture, debris, insects, and contaminants from entering the vent piping. Designed for long-term outdoor performance, Ventrolizer assemblies help maintain proper system operation by allowing unrestricted gas ventilation without compromising the integrity of the installation.
Underwater Connector
CerAnode™ Underwater Connectors provide secure, watertight electrical connections for cathodic protection (CP) systems operating in submerged and marine environments. Engineered to maintain reliable electrical continuity while preventing water intrusion, these connectors are ideal for impressed current cathodic protection (ICCP) and galvanic systems protecting offshore structures, marine infrastructure, and submerged assets.
Splice Kit
CerAnode™ Cable Splice Kits provide secure, moisture-resistant electrical connections for cathodic protection (CP) systems operating in demanding underground, marine, and industrial environments. Designed to restore cable continuity while protecting against moisture intrusion, corrosion, and mechanical damage, these kits help ensure long-term electrical reliability in both impressed current cathodic protection (ICCP) and galvanic systems.